PRODUCTION SERIES

Dual P-12

A dual 12+12-liter system with stainless steel frame, vessels, and piping.

Dimensions

  • Width:  9.8 feet (3 meters)
  • Height: 6.2 feet (1.9 meters)
  • Depth: 4.9 feet (1.5 meters)
  • Weight: 3970 lbs (1800kg)
  • Recommended Room Size: 19 x 16 feet (6 x 5 meters) with a ceiling height of 13 feet (4 meters)

Technical Specifications

  • Voltage: 460 AC-V or 400 AC-V
  • Frequency: 60 Hz or 50 Hz
  • Installed Power: 10 kw
  • Current: 17.2 A

CE or UL certification for the electrical panel is available as an option.
Pressure vessels are ASME-certified, and control system is SIL4-rated.

Configurations

This machine is composed of two pumps, one for COand another one for co-solvent, two extraction vessels, three separation vessels, and a separated chiller and heater. It can reach max pressure (Pmax) of 350 bar and max temperature (Tmax) of 85 °C. There are two pressure set-points: the first one is for extraction vessels and the second one for separation vessels.

There are 5 pressure gauges and voltage can be chosen on request.

Carbon dioxide is continually recycled with a closed circuit for fluid recirculation.  The system has PLC on board and is connected to the internet by an Ethernet network connection. It’s fully automatic and is equipped with a touchscreen.

The system is PED/CE certified and ASME/UL certified.

Pumps

There are two pumps:

  1. The most important is the CO2 pump, the carbon dioxide is the principal solvent for the extraction of apolar chemical compounds.
  2. The secondary pump is used for the release of polar or medium apolar co-solvents during the process – useful for the extraction of chemical compounds with different degrees of polarity.

At the condition of max-pressure, these pumps can ensure a CO2 Flow of 50 kg/h, and Co-solvent Flow of 5 L/h.

The extraction process is based on small variations of solvent’s (CO2) pressure and temperature. These critical operations are ensured by several heat exchangers filled with water, which is heated or cooled by a separated, external chiller and heater.

Chiller

  • Voltage/Frequency: 3 Ph 460/60 V/Hz or 400/50 V/Hz
  • Installed Power: 3.7/5.9 kW/A
  • Size: (WxHxD) 60x140x130 cm (2×4.5×4.2 feet)

Heater

  • Voltage/Frequency: 3 Ph 460/60 V/Hz or 400/50 V/Hz
  • Installed Power: 7.1/11.1 kW/A
  • Size: (WxHxD) 30x55x75 cm (1×1.8×2.4 feet)
  • Water connection in/out: 1″x3.4″ M.

Vessel Volumes

  • Extractor volume 1 & 2: 12 L
  • Extraction canister volume 1 & 2: 10 L
  • Separator 1 volume: 3 L
  • Separators 2 & 3 volumes: 2 L
  • Accumulator volume: 27 L

Other Specifications

  • ASME certified safety valve for each vessel in isolated tubing from the vessel
  • Low headroom hoist
  • 15-inch touchscreen
  • PLC microprocessor Intel i7
  • Compressed air pressure 100 Ψ
  • Compressed air flow 1 CFM/h
  • 2 Back pressure automatic pilot valves
  • 2 Automatic back pressure valves

Single P-12

There’s also an option for a single extraction vessel with 12 L of volume and 10 L of canister volume.